Behaviour of 3D RC frames placed at different angles on shaking table
Küçük Resim Yok
Tarih
2018
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Croatian Soc Civil Engineers-Hsgi
Erişim Hakkı
info:eu-repo/semantics/openAccess
Özet
Behaviour of RC frames placed at different angles (biaxially) on the shaking table is analysed in the paper. The testing was conducted on four two-storey one-bay 3D RC frames scaled down to 1: 6 of the original size, the aim being to analyse defects commonly observed on residential buildings. All specimens had infill walls and similar window openings. The specimens were subjected to sinusoidal dynamic testing. Test results show that different failure modes occurred at all specimens in the X and Y directions.
Açıklama
Anahtar Kelimeler
Reinforced-Concrete Frame, Shaking Table, Dynamic Testing, Failure Mode
Kaynak
Gradevinar
WoS Q Değeri
Q4
Scopus Q Değeri
Q4
Cilt
70
Sayı
3