An Electrochemical Acetylcholinesterase Biosensor Based on Fluorene(bisthiophene) Comprising Polymer for Paraoxon Detection
Küçük Resim Yok
Tarih
2023
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Wiley-V C H Verlag Gmbh
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
In this study, a novel conductive polymer comprising biosensor based on poly-2,2 '-(9,9-dioctyl-9 h-fluorene-2,7-diyl)bistiophene (Poly(BT)) and acetylcholinesterase (AChE) was reported for the determination of paraoxon. This practical biosensor allowed to catalyze electrochemical oxidation of acetylthiocholine (+0.6 V vs. Ag reference). The detection range for acetylcholine chloride (AThCl) with Poly(BT)/AChE was found to be 0.025-4 mM. In pesticide analysis, wide linear ranges from 0.5 to 1 mu g/L and 1 to 14 mu g/L, and a low detection limit of 0.033 mu g/L were estimated. Under optimum operating conditions, the developed biosensor was used for pesticide detection in milk and tap water samples, effectively.
Açıklama
Anahtar Kelimeler
Electrochemical Biosensor, Conjugated Polymer, Acetylcholinesterase, Enzyme Immobilization, Organophosphorus Pesticides