Akkurt, FatihOzselcuk, Aysel2024-02-232024-02-2320231742-82971742-8300https://doi.org/10.1504/IJEX.2023.10059602https://hdl.handle.net/20.500.12452/14836In this study, exergoeconomic analyses of a 1,166 kWp nominal power PV system for polycrystalline, PERC monocrystalline-half cut and PERC monocrystalline panel types were carried out for the climatic conditions of Konya Province in Turkey. The annual energy and exergy efficiencies were determined as 17.2% and 18.5% for PERC monocrystalline-half cut, 16.8% and 18.1% for PERC monocrystalline, 13.8% and 14.8% for polycrystalline, respectively. The SPECO method was used for exergoeconomic analysis. The annual electricity generation costs were determined as 35, 41 and 37$/MWh while the payback periods were calculated as 48, 63 and 53 months for polycrystalline, PERC monocrystalline-half cut and PERC monocrystalline, respectively.eninfo:eu-repo/semantics/openAccessPv SystemExergy EnalysisExergoeconomic AnalysisElectricity Generation CostPayback PeriodExergoeconomic analysis of a photovoltaic plant for different panel typesArticle413337+Q3WOS:00109822930000110.1504/IJEX.2023.10059602