Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • DSpace İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Akdemir, Bayram" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Automated elimination of EOG artifacts in sleep EEG using regression method
    (Tubitak Scientific & Technological Research Council Turkey, 2019) Dursun, Mehmet; Ozsen, Seral; Gunes, Salih; Akdemir, Bayram; Yosunkaya, Sebnem
    Sleep electroencephalogram (EEG) signal is an important clinical tool for automatic sleep staging process. Sleep EEG signal is effected by artifacts and other biological signal sources, such as electrooculogram (EOG) and electromyogram (EMG), and since it is effected, its clinical utility reduces. Therefore, eliminating EOG artifacts from sleep EEG signal is a major challenge for automatic sleep staging. We have studied the effects of EOG signals on sleep EEG and tried to remove them from the EEG signals by using regression method. The EEG and EOG recordings of seven subjects were obtained from the Sleep Research Laboratory of Meram Medicine Faculty of Necmettin Erbakan University. A dataset consisting of 58 h and 6941 epochs was used in the research. Then, in order to see the consequences of this process, we classified pure sleep EEG and artifact-eliminated EEG signals with artificial neural networks (ANN). The results showed that elimination of EOG artifacts raised the classification accuracy on each subject at a range of 1%-1.5%. However, this increase was obtained for a single parameter. This can be regarded as an important improvement if the whole system is considered. However, different artifact elimination strategies combined with different classification methods for another sleep EEG artifact may give higher accuracy differences between original and purified signals.

| Necmettin Erbakan Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Yaka Mahallesi, Yeni Meram Caddesi, Kasım Halife Sokak, No: 11/1 42090 - Meram, Konya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez ayarları
  • Gizlilik politikası
  • Son Kullanıcı Sözleşmesi
  • Geri bildirim Gönder