    Öğe
    First clinical multicenter experience with the new Pipeline Vantage flow diverter
    (Bmj Publishing Group, 2023) Vollherbst, Dominik F.; Cekirge, H. Saruhan; Saatci, Isil; Baltacioglu, Feyyaz; Onal, Baran; Koc, Osman; Rautio, Riitta
    Background Flow diversion is an innovative and increasingly used technique for the treatment of intracranial aneurysms. New flow diverters (FDs) are being introduced to improve the safety and efficacy of this treatment. The aim of this study was to assess the safety, feasibility, and efficacy of the new Pipeline Vantage (PV) FD. Methods Patients with intracranial aneurysms treated with the PV at 10 international neurovascular centers were retrospectively analyzed. Patient and aneurysm characteristics, procedural parameters, complications, and the grade of occlusion were assessed. Results 60 patients with 70 aneurysms (5.0% with acute hemorrhage, 90.0% located in the anterior circulation) were included. 82 PVs were implanted in 61 treatment sessions. The PV could be successfully implanted in all treatments. Additional coiling was performed in 18.6%, and in-stent balloon angioplasty (to enhance the vessel wall apposition) in 24.6%. Periprocedural technical complications occurred in 24.6% of the treatments, were predominantly FD deployment problems, and were all asymptomatic. The overall symptomatic complication rate was 8.2% and the neurological symptomatic complication rate was 3.3%. Only one symptomatic complication was device-related (perforator artery infarctions leading to stroke). After a mean follow-up of 7.1 months, the rate of complete aneurysm occlusion was 77.9%. One patient (1.7%) died due to aneurysmal subarachnoid hemorrhage which occurred before treatment, unrelated to the procedure. Conclusions The new PV FD is safe and feasible for the treatment of intracranial aneurysms. The short-term occlusion rates are promising but need further assessment in prospective long-term follow-up studies.
  • Küçük Resim Yok
    Öğe
    Long-term clinical and angiographic follow-up results of the dual-layer flow diverter device (FRED) for the treatment of intracranial aneurysms in a multicenter study
    (Springer, 2021) Dinc, Hasan; Saatci, Isil; Oguz, Sukru; Baltacioglu, Feyyaz; Yildiz, Altan; Donmez, Halil; Belet, Umit
    Purpose Our aim was to determine the long-term safety and efficacy of the Flow Re-Direction Endoluminal Device (FRED) in this multicenter study with prospective design. Materials-method This study included 136 consecutive patients with 155 aneurysms treated between March 2013 and June 2016 in 10 centers. Twenty-two (16.2%) patients presented with rupture of the index aneurysm. Large/giant aneurysms comprised 1/3 of the cohort. Adjuvant coil use during the treatment was 15.5%. The effectiveness measure in the study was the percentage of aneurysms with stable occlusion at follow-up. Results Vascular imaging follow-up was performed at least once in 131/136 (96.3%) patients with 148/155 (95.5%) aneurysms up to 75 months (mean: 37.3 months; median: 36 months according to latest follow-up), and 102/155(65.8%) aneurysms in 90/136 (66.2%) patients had >= 24-month control. According to the latest controls, the overall stable occlusion rate was 91.9% (95% CI, 87.5 to 96.3%). Three out of 148 aneurysms with follow-up were retreated (2%, 95% CI 0.0 to 4.3%). Adverse events were noted in 19/136 (14%, 95% CI, 9 to 21%) patients with a morbidity of 1.5% (95% CI, 0.0 to 3.5%). Mortality was 1/136 (0.7%, 95% CI, 0.02 to 2.2%) and was unrelated to aneurysm treatment. In-stent stenosis (ISS) was detected in 10/131 of the patients with follow-up (7.6%, 95% CI; 3.1 to 12.2%), only one being symptomatic. No adverse events have occurred in any of the patients with follow-up after 24 months, except the one resulting from ISS. Conclusion In the treatment of cerebral aneurysms which were candidates for flow diversion technique, this study showed long-term efficacy of FRED with good safety and occlusion rates.

| Necmettin Erbakan Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Yaka Mahallesi, Yeni Meram Caddesi, Kasım Halife Sokak, No: 11/1 42090 - Meram, Konya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez ayarları
  • Gizlilik politikası
  • Son Kullanıcı Sözleşmesi
  • Geri bildirim Gönder