Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • DSpace İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Bosnali, Wael" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Voltammetric Determination of Acrylamide Using Coal Tar Pitch Modified Pencil Graphite Electrode by SWV
    (Springer, 2023) Korkmaz, Seyma; Bosnali, Wael; Mulazimoglu, Ibrahim Ender; Mulazimoglu, Aysen Demir
    The adverse effects of acrylamide (AA) on humans are becoming clear, especially after a series of related investigations reported the dependence on consuming foods prepared by exposure to high temperatures for a long-time and cancer risk. Accurate determination of AA in food samples at trace amount is considered the first step to overcome this significant problem. The determination of AA using coal tar pitch modified pencil graphite (PGE/CTP) electrode was reported. The bare PGE and PGE/CTP electrodes were characterized using microscopic imaging technique scanning electron microscopy (SEM). The electrochemical behavior of AA was studied on PGE/CTP electrode in different medium acidities (pH) of phosphate and Briton-Robinson (BR) buffer solutions by employing square wave voltammetry (SWV). Linear sweep voltammetry (LSV) technique was applied to determine the mass transfer mode of AA from bulk solution to the PGE/CTP electrode surface. The optimum conditions were using phosphate buffer solution (PBS) at pH 7.0. The detectability of AA on the surfaces of bare PGE and PGE/CTP electrodes was compared, and the suitability of PGE/CTP electrode usage was determined. The linear relationship between peak current and AA concentration was in the range of 1000.0 to 0.5 nM. The limit of detection of AA was 0.2094 nM, and the limit of quantitation was 0.6912 nM. In addition, the PGE/CTP electrode as a sensor was successfully used for the determination of AA in the instant coffee sample.

| Necmettin Erbakan Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Yaka Mahallesi, Yeni Meram Caddesi, Kasım Halife Sokak, No: 11/1 42090 - Meram, Konya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez ayarları
  • Gizlilik politikası
  • Son Kullanıcı Sözleşmesi
  • Geri bildirim Gönder