Yazar "Evrin, Togay" seçeneğine göre listele
Listeleniyor 1 - 5 / 5
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Etiological factors and management in priapism patients and attitude of emergency physicians(Pagepress Publ, 2017) Sonmez, Mehmet Giray; Sonmez, Leyla Ozturk; Taskapu, Hakki Hakan; Kara, Cengiz; Dundar, Zerrin Defne; Goger, Yunus Emre; Evrin, TogayObjective: To present the underlying etiological factors in patients referring with priapism, sharing how they are managed according to etiology and priapism type together with our experiences, creating awareness so that urologists and emergency physicians may play a more active role together in priapism management. Materials and methods: Patients referring to emergency service with priapism were examined. Penile Doppler ultrasonography (PDU) and/or corporeal aspiration and blood gas analysis were made in order to determine priapism type after anamnesis and physical examination. The most appropriate treatment option was chosen and applied on the patients considering priapism type, underlying etiological factors and priapism time. Presence of a statistical difference between etiological factors causing priapism, priapism type and applied treatment methods was calculated using Chi square (chi 2) test. Results: A total of 51 patients referring to emergency service with priapism attacks for 53 times were included in the evaluation. When compared to other etiological factors, number of priapism cases developing secondary to papaverine after PDU was found statistically significantly high (p < 0.001). Ischemic priapism ratio was detected statistically higher compared to other groups (p < 0.001). Aspiration and/or irrigation treatment were the most common method used for treatment at a statistically significant level (p < 0.001). All patients (100%) were hospitalized in urology service without applying any treatment in emergency service and had treatment and intervention under the control of the urologist. Conclusions: Application of non-invasive treatments in suitable priapism patients would protect patients from invasive painful interventions. We believe that emergency physicians should be more effective in priapism phase management and at least noninvasive treatment phase.Öğe Evaluating Stable Chronic Obstructive Pulmonary Disease by Ultrasound(Hindawi Ltd, 2019) Evrin, Togay; Korkut, Semih; Sonmez, Leyla Ozturk; Szarpak, Lukasz; Katipoglu, Burak; Smereka, Jacek; Guven, RamazanBackground and Aim. The purpose of the study was to evaluate the relationship between COPD severity and the diaphragmatic function measured by point-of-care US in patients with stable COPD. Method. A total of 61 patients with COPD and 40 healthy subjects who had been admitted to Ufuk University Hospital between December 2018 and May 2019 were enrolled. Point-of-care US was performed, and lung silhouette and anterior, right, and left hemidiaphragm method in M-mode were used to evaluate the diaphragm. Results. The point-of-care US measurements, lung silhouette method right (Lung Sil R), lung silhouette method left (Lung Sil L), right hemidiaphragm US method in B-mode (Ant B-Mode R), and right hemidiaphragm US method in M-mode (Ant M-Mode R), were significantly different among groups (P < 0.001 for each). FEV1 was strongly correlated with Lung Sil R, Lung Sil L, Ant B-Mode R, and Ant M-Mode R (r = 0.963, P < 0.001; r = 0.956, P < 0.001; r = 0.953, P < 0.001; and r = 0.917, and P < 0.001, respectively). Negative correlations were detected between the number of exacerbations per year and Lung Sil R and the number of exacerbations per year and Ant M-Mode R (r = -0.599, P < 0.001 and r = -0.587, and P < 0.001, respectively). Conclusion. In this study, FEV1 and annual number of exacerbations turned out to be strongly correlated US findings. The use of US in COPD patients could help to support clinical decision, but further clinical studies are necessary to confirm those findings.Öğe The Impact of Lung Ultrasound on Coronavirus Disease 2019 Pneumonia Suspected Patients Admitted to Emergency Departments(Lippincott Williams & Wilkins, 2021) Sonmez, Leyla Ozturk; Katipoglu, Burak; Vatansev, Hulya; Kaykisiz, Eylem Kuday; Yuce, Nalan; Szarpak, Lukasz; Evrin, TogayObjective The aim of this study was to identify the sensitivity and specificity of lung ultrasound (LUS) and show its place in diagnosing patients with known coronavirus disease 2019 (COVID-19) pneumonia, according to chest computed tomography and the COVID-19 reporting and data system (CO-RADS). Methods Nineteen patients who admitted to a single university hospital emergency department between March 5, 2020, and April 27, 2020, describing dyspnea were included in the study and underwent LUS by a single emergency specialist. The patient population was divided into 2 groups, COVID-19 positive and negative, and the sensitivity and specificity of LUS according to chest computed tomography were calculated for COVID-19 pneumonia diagnosis. In the subgroup analysis, the patient group was divided into real-time reverse transcription-polymerase chain reaction positive (n = 7) and negative (n = 12), and sensitivity and specificity were calculated according to the CO-RADS. Results According to the CO-RADS, significant differences were detected between the LUS positive and negative groups in terms of COVID-19 pneumonia presence. Only 1 patient was evaluated as CO-RADS 2 in the LUS positive group, and 2 patients were evaluated as CO-RADS 4 in the LUS negative group (P = 0.04). The sensitivity of LUS according to the CO-RADS for COVID-19 pneumonia diagnosis was measured to be 77.78% (95% confidence interval [CI], 39.9%-97.1%), specificity was 90% (95% CI, 55.5%-99.75%), positive predictive value was 87.5% (95% CI, 51.35%-97.8%), and accuracy was 84.21% (95% CI, 60.4%-96.62%; P = 0.004). Conclusions In conclusion, LUS is easily used in the diagnosis of COVID-19 pneumonia because it has bedside application and is fast, easy to apply, reproducible, radiation free, safe for pregnant women, and cheap.Öğe Is There a Difference Between the Readabilities of Informed Consent Forms Used for Procedures in the Emergency Services of State and University Hospitals in Turkey?(2018) Öztürk Sönmez, Leyla; Sönmez, Mehmet Giray; Mustafa Kürşat, Ayrancı; Evrin, Togay; Katipoğlu, Burak; Cander, BaşarAim: The aim of the present study was to evaluate the readability levels of informed consent forms (ICFs) used for procedures in the emergency services of state and university hospitals by comparing through readability formulas.Materials and Methods: ICFs used in emergency medicine clinics in different university and state hospitals in Turkey were collected, and forms that were the same were included in the evaluation only once. A total of 32 ICFs, with 15 from university hospitals and 17 from state hospitals, were evaluated. Average word number, syllable number, and words with syllable number of four and above were calculated. Different formulas were used to determine readability levels.Results: Although the readability of ICFs used in university hospitals was found to be better than those in state hospitals, the readability levels of the ICFs for both groups were detected to have medium difficulty according to the Atesman formula, very difficult according to the Flesch-Kincaid formula, difficult according to the Gunning-Fog formula, and at high school level according to the Bezirci-Yilmaz formula.Conclusion: In conclusion, the readability rates of emergency procedure ICFs in both state hospitals and university hospitals were detected to be rather low according to the present study. The education level of our country and the local environment should be considered while preparing these ICFs.Öğe Pseudopneumothorax: Emphysema Case Mimicking Pneumothorax(Emergency Medicine Physicians Assoc Turkey, 2019) Sonmez, Leyla Ozturk; Evrin, Togay; Ayranci, Mustafa Kursat; Unluer, Erden ErolBedside lung ultrasound (LUS) is generally emergency rooms for the patients suspected to have lung pathology. LUS is especially important for quick diagnosis and fast treatment, especially in unstable patients. Pneumothorax is the condition of air entering between pleural plaques and lung being separated from the thoracic wall. Typically, there is a low amount of lubricating fluid between visceral pleura covering the lung and parietal pleura covering the inner face of the thoracic wall. Emphysema is the abnormal widening of air sacs distal to the terminal bronchioles with the destruction of alveolar walls without fibrosis, and it is one of the obstructive lung diseases. Cases, where emphysema is confused with pneumothorax, were also defined rarely in the literature. We wanted to create awareness on the place of ultrasound on pneumothorax diagnosis by sharing the emphysema case imitating pneumothorax in LUS seen rather rare in literature.