Yazar "Kutahya, Harun" seçeneğine göre listele
Listeleniyor 1 - 3 / 3
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Closed Extensor Indicis Proprius Tendon Rupture Presenting Mass Clinic on Dorsal Side of the Wrist(Modestum Ltd, 2013) Kutahya, Harun; Gulec, Ali; Acar, Mehmet A.; Guzel, Yunus; Karalezli, Mustafa N.; Toker, SerdarA 28 years old male constructor referred to our clinic for a mass on the dorsal side of the left wrist. He has constricted his hand to the plaster cast machine in hyperflexion posture one month ago and swelling complaint has begun one week ago. MRI revealed tenosynovitis. A wide organized hematoma was appeared in the 4th extensor compartment in the surgical exploration of the patient and it was observed that extensor indicis proprius tendon has detached from the musculotendineous region. Common extensor tendon of the second finger was intact. Tenodesis to the distal end of the ruptured tendon to the intact common extensor tendon by side to side surgical suture technique was performed. There were complete extension in the 2nd finger at the 2nd month after the surgery.Öğe Tendon Interposition and Ligament Reconstruction with ECRL Tendon in the Late Stages of Kienbock's Disease: A Cadaver Study(Hindawi Publishing Corporation, 2013) Karalezli, Nazim; Uz, Aysun; Esmer, Ali Firat; Demirtas, Mehmet; Tasci, Arzu Gul; Kutahya, Harun; Ulusoy, GurhanBackground. The optimal surgical treatment for Kienbock's disease with stages IIIB and IV remains controversial. A cadaver study was carried out to evaluate the use of coiled extensor carpi radialis longus tendon for tendon interposition and a strip obtained from the same tendon for ligament reconstruction in the late stages of Kienbock's disease. Methods. Coiled extensor carpi radialis longus tendon was used to fill the cavity of the excised lunate, and a strip obtained from this tendon was sutured onto itself after passing through the scaphoid and the triquetrum acting as a ligament to preserve proximal row integrity. Biomechanical tests were carried out in order to evaluate this new ligamentous reconstruction. Results. It was biomechanically confirmed that the procedure was effective against axial compression and distributed the upcoming mechanical stress to the distal row. Conclusion. Extensor carpi radialis longus tendon has not been used for tendon interposition and ligament reconstruction in the treatment of this disease before. In view of the biomechanical data, the procedure seems to be effective for the stabilization of scaphoid and carpal bones.Öğe Transverse Carpal Ligament and Forearm Fascia Release for the Treatment of Carpal Tunnel Syndrome Change the Entrance Angle of Flexor Tendons to the A1 Pulley: The Relationship between Carpal Tunnel Surgery and Trigger Finger Occurence(Hindawi Ltd, 2013) Karalezli, Nazim; Kutahya, Harun; Gulec, Ali; Toker, Serdar; Karabork, Hakan; Ogun, Tunc C.Purpose. The appearance of trigger finger after decompression of the carpal tunnel without a preexisting symptom has been reported in a few articles. Although, the cause is not clear yet, the loss of pulley action of the transverse carpal ligament has been accused mostly. In this study, we planned a biomechanical approach to fresh cadavers. Methods. The study was performed on 10 fresh amputees of the arm. The angles were measured with (1) the transverse carpal ligament and the distal forearm fascia intact, (2) only the transverse carpal ligament incised, (3) the distal forearm fascia incised to the point 3 cm proximal from the most proximal part of the transverse carpal ligament in addition to the transverse carpal ligament. The changes between the angles produced at all three conditions were compared to each other. Results. We saw that the entrance angle increased in all of five fingers in an increasing manner from procedure 1 to 3, and it was seen that the maximal increase is detected in the middle finger from procedure 1 to procedure 2 and the minimal increase is detected in little finger. Discussion. Our results support that transverse carpal ligament and forearm fascia release may be a predisposing factor for the development of trigger finger by the effect of changing the enterance angle to the A1 pulley and consequently increase the friction in this anatomic area. Clinical Relevance. This study is a cadaveric study which is directly investigating the effect of a transverse carpal ligament release on the enterance angle of flexor tendons to A1 pulleys in the hand.