Yazar "Polat, Serdar" seçeneğine göre listele
Listeleniyor 1 - 3 / 3
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe The effect of a diode laser and traditional irrigants on the bond strength of self-adhesive cement(Korean Acad Prosthodontics, 2013) Tuncdemir, Ali Riza; Yildirim, Cihan; Ozcan, Erhan; Polat, SerdarPURPOSE. The purpose of this study was to compare the effect of a diode laser and traditional irrigants on the bond strength of self-adhesive cement. MATERIALS AND METHODS. Fifty-five incisors extracted due to periodontal problems were used. All teeth were instrumented using a set of rotary root canal instruments. The post spaces were enlarged for a No.14 (diameter, 1.4 mm) Snow light (Abrasive technology, OH, USA) glass fiber reinforced composite post with matching drill. The teeth were randomly divided into 5 experimental groups of 11 teeth each. The post spaces were treated with the followings: Group 1: 5 mL 0.9% physiological saline; Group 2: 5 mL 5.25% sodium hypochlorite; Group 3: 5 mL 17% ethylene diamine tetra acetic acid (EDTA), Group 4: 37% orthophosphoric acid and Group 5: Photodynamic diode laser irradiation for 1 minute after application of light-active dye solution. Snow light posts were luted with self-adhesive resin cement. Each root was sectioned perpendicular to its long axis to create 1 mm thick specimens. The push-out bond strength test method was used to measure bond strength. One tooth from each group was processed for scanning electron microscopic analysis. RESULTS. Bond strength values were as follow: Group 1 = 4.15 MPa; Group 2 = 3.00 MPa; Group 3 = 4.45 MPa; Group 4 = 6.96 MPa; and Group 5 = 8.93 MPa. These values were analysed using one-way ANOVA and Tukey honestly significant difference test (P<.05). Significantly higher bond strength values were obtained with the diode laser and orthophosphoric acid (P<.05). There were no differences found between the other groups (P>.05). CONCLUSION. Orthophosphoric acid and EDTA were more effective methods for removing the smear layer than the diode laser. However, the diode laser and orthophosphoric acid were more effective at the cement dentin interface than the EDTA, Therefore, modifying the smear layer may be more effective when a self-adhesive system is used.Öğe Evaluation of the bond strength between aged composite cores and luting agent(Korean Acad Prosthodontics, 2015) Polat, Serdar; Cebe, Fatma; Tuncdemir, Aliriza; Ozturk, Caner; Usumez, AshhanPURPOSE The aim of this study was to evaluate effect of different surface treatment methods on the bond strength between aged composite-resin core and luting agent. MATERIALS AND METHODS. Seventy-five resin composites and also seventy-five zirconia ceramic discs were prepared. 60 composite samples were exposed to thermal. aging (10;000 cycles, 5 to 55 degrees C) and different surface treatment. All specimens were separated into 5 groups. (n=15): 1) Intact specimens 2) Thermal aging-air polishing 3) Thermal aging- Er:YAG laser irradiation 4) Thermal aging- acid etching 5) Thermal-aging. All specimens were bonded to the zirconia discs with resin cement and fixed to universal testing machine and bond strength testing loaded to failure with a crosshead speed of 0.5 mm/min. The fractured surface was classified as adhesive failure, cohesive failure and adhesive-cohesive failure. The bond strength data was statistically compared by the Kruskal-Wallis method complemented by the Bonferroni correction Mann-Whitney U test. The probability level for statistical significance was set at alpha=.05. RESULTS. Thermal aging and different surface treatment methods have significant effect on the bond strength between composite-resin cores and luting-agent (P<.05). The mean baseline bond strength values ranged between 7.07 +/- 2.11 and 26.05 +/- 6.53 N. The highest bond strength of 26.05 +/- 6.53 N was obtained with Group 3. Group 5 showed the lowest value of bond strength. CONCLUSION. Appropriate surface treatment method should be applied to aged composite resin cores or aged-composites restorations should be replaced for The optimal bond strength and the clinical success.Öğe Evaluation of the fracture resistance of root filled thin walled teeth restored with different post systems(Elsevier Science Bv, 2019) Ozturk, Caner; Polat, Serdar; Tuncdemir, Makbule; Gonuldas, Fehmi; Sekar, EmreBackground: Restoration of the teeth with extensive root canals with different post systems is a challenge for clinicians. Evaluation of these systems is important for clinical success. The aim of this study was to compare the fracture resistance and fracture mode of endodontically treated thin-walled teeth which restored with different post systems. Methods: Eighty extracted and endodontically treated maxillary canines were divided into 4 groups (n = 20) and the thickness of the radicular dentin walls was reduced by using diamond burs. Each root was embedded in an autopolymerizing resin with a 0.25 mm layer of vinyl polysiloxane material to simulate the periodontal ligament. The subgroups were restored with one of the following post systems: only composite resin (Group 1), cast post (Group 2), glass-fiber post (Group 3), and I-TFC post (Group 4). The samples were subjected to a gradually increasing force (0,5 mm/min). The force required to fracture was recorded, and the data were analyzed with ANOVA, Tukey tests and Chi-Square test (p < 0.05). Results: The highest fracture resistance was recorded for Group 2, followed by the Group 3, Group 4, and Group 1. Differences in the fracture resistance of teeth were significant among the groups (p < 0.05). The fracture resistance of Group 4 was significantly different than the other tested post systems (p < 0.05). Conclusions: The lowest fracture resistance was recorded for Group 1, but among all post systems, Group 4 had the lowest fracture resistance. The fracture mode of the fiber posts (Radix and I-TFC posts) would permit repair of the tooth.