Effects of operation temperature and reactant gas humidity levels on performance of PEM fuel cells

Küçük Resim Yok

Tarih

2016

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Pergamon-Elsevier Science Ltd

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

In this study, the effects of operation conditions on the performance of a polymer electrolyte membrane fuel cell are investigated and the results are presented together with a comprehensive literature review on the related topics. The cells with 25 cm(2) active area are tested for different inlet gas humidification levels and inlet temperatures, operating temperatures and oxidant type. The cells are characterized by the performance curves together with the cell resistance measurements. The results indicate that the humidification of the inlet gases positively affect the cell performance. However, the improvement in the cell performance is higher when the cathode gas is humidified. In addition, the operating temperature and the inlet gas temperatures are found to be the most significant parameters. The cell performance tends to increase significantly with increasing the operating and inlet gas temperatures. The effect of the oxidant type is also considered and the cell tested with pure oxygen shows slightly higher performance. (C) 2016 Elsevier Ltd. All rights reserved.

Açıklama

Anahtar Kelimeler

Relative Humidity, Pem Fuel Cell, Membrane Conductivity, Mass Transfer Resistance, Review

Kaynak

Renewable & Sustainable Energy Reviews

WoS Q Değeri

Q1

Scopus Q Değeri

Q1

Cilt

59

Sayı

Künye