Corneal Thickness During Corneal Collagen Cross-Linking with Isotonic Riboflavin Solution without Dextran

dc.contributor.authorOltulu, Refik
dc.contributor.authorDonbaloglu, Meryem
dc.contributor.authorSatirtav, Gunhal
dc.contributor.authorZengin, Nazmi
dc.contributor.authorOzkagnici, Ahmet
dc.date.accessioned2024-02-23T14:38:20Z
dc.date.available2024-02-23T14:38:20Z
dc.date.issued2014
dc.departmentNEÜen_US
dc.description.abstractObjectives: To monitor the corneal thickness change during the dextran-free isotonic riboflavin solution-aided corneal collagen cross-linking procedure in keratoconus patients. Materials and Methods: Corneal thickness measurements during the corneal collagen cross-linking (CXL) treatment for progressive keratoconus were evaluated. The corneal thickness measurements were obtained with ultrasonic pachymetry device at five different time points: 0, 15, and 30 minutes after epithelial removal and 15 and 30 minutes after the initiation of UVA irradiation. Results: Twenty-four eyes of 24 patients with progressive keratoconus were included in the study. The thinnest pachymetric values obtained at the 0, 15, and 30 minute measurements after corneal deepithelisation were 409.38 +/- 10.43 mu m (383-435 mu m), 434.56 +/- 17.68 mu m (400-485 mu m), and 457.44 +/- 21.78 mu m (428-516 mu m), respectively. Pachymetric values obtained at 15 and 30 minutes after UVA application to the cornea were 471.69 +/- 23.38 mu m (439-526 mu m) and 482.63 +/- 23.69 mu m (436-524 mu m), respectively. The gradual increase was found to be statistically significant when each measurement was compared with the previous values (p < 0.001). Conclusion: We found that the corneal thickness was not decreased during the CXL with dextran-free isotonic riboflavin solution; on the contrary, corneal thickness was increased regularly during the procedure.en_US
dc.identifier.doi10.4274/tjo.08831
dc.identifier.endpage274en_US
dc.identifier.issn1300-0659
dc.identifier.issn2147-2661
dc.identifier.issue4en_US
dc.identifier.scopus2-s2.0-84907308196en_US
dc.identifier.startpage272en_US
dc.identifier.urihttps://doi.org/10.4274/tjo.08831
dc.identifier.urihttps://hdl.handle.net/20.500.12452/16454
dc.identifier.volume44en_US
dc.identifier.wosWOS:000219228300005en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isotren_US
dc.publisherTurkish Ophthalmological Socen_US
dc.relation.ispartofTurk Oftalmoloji Dergisi-Turkish Journal Of Ophthalmologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectKeratoconusen_US
dc.subjectCollagen Cross-Linkingen_US
dc.subjectCorneal Thicknessen_US
dc.titleCorneal Thickness During Corneal Collagen Cross-Linking with Isotonic Riboflavin Solution without Dextranen_US
dc.typeArticleen_US

Dosyalar