Clinical Characteristics and Outcome of Cardiovascular Implantable Electronic Device Infections in Turkey
Küçük Resim Yok
Tarih
2016
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Sage Publications Inc
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
Infection is one of the most devastating outcomes of cardiovascular implantable electronic device (CIED) implantation and is related to significant morbidity and mortality. In our country, there is no evaluation about CIED infection. Therefore, our aim was to investigate clinical characteristics and outcome of patients who had infection related to CIED implantation or replacement. The study included 144 consecutive patients with CIED infection treated at 11 major hospitals in Turkey from 2005 to 2014 retrospectively. We analyzed the medical files of all patients hospitalized with the diagnosis of CIED infection. Inclusion criteria were definite infection related to CIED implantation, replacement, or revision. Generator pocket infection, with or without bacteremia, was the most common clinical presentation, followed by CIED-related endocarditis. Coagulase-negative staphylococci and Staphylococcus aureus were the leading causative agents of CIED infection. Multivariate analysis showed that infective endocarditis and ejection fraction were the strongest predictors of in-hospital mortality.
Açıklama
Anahtar Kelimeler
Pacemaker, Implantable Defibrillator, Cardiac Resynchronization Therapy, Infection, Postoperative Complications
Kaynak
Clinical And Applied Thrombosis-Hemostasis
WoS Q Değeri
Q3
Scopus Q Değeri
Q2
Cilt
22
Sayı
5