A Study of Energy Efficiency Simulation Programs and Energy Saving Optimization Analysis of Building Envelopment Parameters in Turkey

dc.contributor.authorBaneaez, Mustafa Obaid Omar
dc.contributor.authorAkkoyunlu, Mustafa Tahir
dc.date.accessioned2024-02-23T14:29:16Z
dc.date.available2024-02-23T14:29:16Z
dc.date.issued2023
dc.departmentNEÜen_US
dc.description.abstractThis study focused on optimizing energy consumption in buildings by improving the building envelope, which accounts for a significant portion of heating and cooling energy usage. The research took an existing building in the Konya-Meram region as an example and conducted experiments on insulation, window-to-wall ratio, and glass thickness. Simulations were performed considering the climate of the Turkey-Konya region for comparative analy-sis. Various programs, such as Revit, Ecotect, Hap, and the Izoder TS-825 calculator (the Turkish standard) were utilized to evaluate energy efficiency. The results of the comparative analysis indicated that the Ecotect program provides the closest match to the calculations, hence enabling optimization experiments throughout the study. The optimal insulation thickness was determined to be between 7-11 cm; implementing an insulation thickness of 11 cm results in a substantial 46.71% reduction in heating load and an overall annual energy savings of 3.896%. However, further increases in insulation thickness beyond 11 cm do not yield significant energy savings. Regard-ing window-to-wall ratios, the optimal ratio in Konya was determined to be 75%, resulting in savings of 5.04%. In conclusion, this study emphasized the importance of the building envelope for energy efficiency and presented optimized solutions for insulation, window-to-wall ratio, and glass thickness in Konya city. The results of this study make a valuable contribution towards achieving notable reductions in energy consumption and highlight the possibility of enhancing energy efficiency in the structures located in the study area.en_US
dc.identifier.doi10.12911/22998993/169178
dc.identifier.endpage217en_US
dc.identifier.issn2299-8993
dc.identifier.issue9en_US
dc.identifier.scopus2-s2.0-85166054448en_US
dc.identifier.scopusqualityQ3en_US
dc.identifier.startpage202en_US
dc.identifier.urihttps://doi.org/10.12911/22998993/169178
dc.identifier.urihttps://hdl.handle.net/20.500.12452/14636
dc.identifier.volume24en_US
dc.identifier.wosWOS:001042571000003en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherPolish Soc Ecological Engineering-Ptieen_US
dc.relation.ispartofJournal Of Ecological Engineeringen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectEnergy Efficiencyen_US
dc.subjectOptimal Thicknessen_US
dc.subjectEcotecten_US
dc.subjectWindow -Wall Ratioen_US
dc.subjectSimulationen_US
dc.titleA Study of Energy Efficiency Simulation Programs and Energy Saving Optimization Analysis of Building Envelopment Parameters in Turkeyen_US
dc.typeArticleen_US