Effect of activated chlorhexidine and irritrol with photon-induced-photoacoustic-streaming and EDDY® on the dislocation resistance of biodentine
Küçük Resim Yok
Tarih
2022
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Wolters Kluwer Medknow Publications
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
Background: Irrigant activation techniques, which are more effective in anatomically complex areas, can be used to maximize irrigant efficacy. Aim: This in vitro study aimed to evaluate the efficacy of different agitation techniques on the dislocation resistance of Biodentine to the root canal dentin. Materials and Methods: Seventy single-rooted teeth divided into seven experimental groups (n = 10); Group I-Irritrol/Photon-induced-photoacoustic-streaming (PIPS), Group II-Irritrol/EDDY (R), Group III- Irritrol/Syringe-needle-irrigation (SNI), Group IV-Chlorhexidine-gluconate (CHX)/PIPS, Group V-CHX/EDDY (R), Group VI-CHX/SNI, Group VII-Saline. The midroot dentin slice was obtained from each tooth, and Biodentine was condensed with hand pluggers into the root canal lumen. The push-out bond strength values were measured using a universal testing machine. Each sample was categorized into one of the three failure modes: adhesive/cohesive/mixed. Scanning-Electron-Microscopy (SEM) was used to conduct the analyses, and the composition of Biodentine was analyzed using Energy-Dispersive Spectroscopy. The One-way ANOVA, post-hoc Tukey's test, and the Chi-square test were used for statistical analysis. Results: The push-out bond strength values of Biodentine showed that Group VII-Saline had a statistically significant difference (P = 0.002), however, the differences between the other groups were not statistically significant (P = 0.922). The percentages of the failure modes of the samples showed that there was a higher rate of mixed failure except for Group VII-Saline. SEM examination showed that Group VII-Saline had no open dentinal tubules, whereas the other groups, particularly the Irritrol groups, had open dentinal tubule areas. Conclusions: Within the scope of the study, using Irritrol or CHX as the final irrigation in the root canal treatment did not result in differences in the dislocation resistance of Biodentine to root canal dentin when PIPS and EDDY (R) were used.
Açıklama
Anahtar Kelimeler
Biomaterials, Er-Yag Lasers, Push-Out Bond Strength, Surface Treatment By Chemical Solutions
Kaynak
Nigerian Journal Of Clinical Practice
WoS Q Değeri
Q4
Scopus Q Değeri
Q3
Cilt
25
Sayı
5