Utilizing of 2-Amino-3-hydroxypyridine Modified Glassy Carbon Electrode to Detect Copper(II) Ions
dc.contributor.author | Mulazimoglu, Aysen Demir | |
dc.date.accessioned | 2024-02-23T14:31:28Z | |
dc.date.available | 2024-02-23T14:31:28Z | |
dc.date.issued | 2013 | |
dc.department | NEÜ | en_US |
dc.description.abstract | In this paper 2-amino-3-hydroxypyridine modified glassy carbon electrode was used for the electrochemical analysis of trace copper(II) ions by square wave voltammetry technique. The modification of the glassy carbon electrode by 2-amino-3-hydroxypyridine soution was performed in the potential range between -150 mV and +600 mV by 30 cycles at 100 mV s(-1) potential scan rate in non-aqueous media by cyclic voltammetry. The surface characterizations of this sensor electrode were performed by cyclic voltammetry. A lower detection limit would be reached in the presence of Britton-Robinson buffer solutin at pH 5 for determination of Cu(II) ions by square wave voltammetry. The voltammetric response of the electrode was linear within the Ci(II) ion concentration range from 1.0 x 10(-12) M to 1.0 x 10(-6) M and the detection limit of 1.0 x 10(-12) M. The modified electrode offered and excellent way, with a high stability, simple, rapid, low cost and reusability, for selective determination of Cu(II) ions in Acigol lake (in Afyonkarahisar, Turkey) water sample. | en_US |
dc.identifier.doi | 10.14233/ajchem.2013.14393 | |
dc.identifier.endpage | 3494 | en_US |
dc.identifier.issn | 0970-7077 | |
dc.identifier.issn | 0975-427X | |
dc.identifier.issue | 6 | en_US |
dc.identifier.scopus | 2-s2.0-84875145584 | en_US |
dc.identifier.scopusquality | Q4 | en_US |
dc.identifier.startpage | 3491 | en_US |
dc.identifier.uri | https://doi.org/10.14233/ajchem.2013.14393 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12452/15207 | |
dc.identifier.volume | 25 | en_US |
dc.identifier.wos | WOS:000317245900131 | en_US |
dc.identifier.wosquality | Q4 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Asian Journal Of Chemistry | en_US |
dc.relation.ispartof | Asian Journal Of Chemistry | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | 2-Amino-3-Hydroxypyridine | en_US |
dc.subject | Sensor Electrode | en_US |
dc.subject | Copper(Ii) Ions | en_US |
dc.subject | Surface Modification | en_US |
dc.subject | Surface Characterization | en_US |
dc.title | Utilizing of 2-Amino-3-hydroxypyridine Modified Glassy Carbon Electrode to Detect Copper(II) Ions | en_US |
dc.type | Article | en_US |