Effect of Eye Rubbing on Corneal Biomechanical Properties and Intraocular Pressure

dc.contributor.authorOltulu, Refik
dc.contributor.authorDonbaloglu, Meryem
dc.contributor.authorSatirtav, Gunhal
dc.contributor.authorOkka, Mehmet
dc.contributor.authorOzkagnici, Ahmet
dc.date.accessioned2024-02-23T14:38:20Z
dc.date.available2024-02-23T14:38:20Z
dc.date.issued2014
dc.departmentNEÜen_US
dc.description.abstractObjectives: To determine whether corneal biomechanical properties and intraocular pressure (IOP) are affected by eye rubbing. Materials and Methods: Healthy individuals, aged between 15 and 50 years, without any ocular pathological signs were included. Corneal biomechanical parameters, Goldmann-equivalent intraocular pressure (IOPg), corneal-compensated intraocular pressure (IOPcc), corneal resistance factor (CRF), and corneal hysteresis (CH) values were measured using an ocular response analyzer (ORA). Measurements were taken at baseline and immediately after 30 seconds of eye rubbing. ORA parameters before and after eye rubbing were analyzed using student's t test. A p-value less than 0.05 was considered statistically significant. Results: We included eighty-one eyes of 53 individuals with a mean age of 32 +/- 10.11(15-50) years. Before eye rubbing, the mean measurement values were as follows: CH 10.93 +/- 1.69 mmHg, CRF 10.82 +/- 1.78 mmHg, IOPg 15.76 +/- 3.18 mmHg, and IOPcc 15.74 +/- 2.69 mmHg. The mean values after eye rubbing were: CH 11.11 +/- 1.52 mmHg, CRF 10.54 +/- 1.56 mmHg, IOPg 14.32 +/- 3.10 mmHg, and IOPcc 14.20 +/- 2.77 mmHg. The decrease in CRF, IOPg, and IOPcc was statistically significant, while the change in CH was found to be statistically insignificant. Conclusion: CRF, IOPg, and IOPcc decreased significantly after eye rubbing and this should be considered before taking any ORA measurements and interpreting the results.en_US
dc.identifier.doi10.4274/tjo.37267
dc.identifier.endpage271en_US
dc.identifier.issn1300-0659
dc.identifier.issn2147-2661
dc.identifier.issue4en_US
dc.identifier.scopus2-s2.0-84907309076en_US
dc.identifier.startpage268en_US
dc.identifier.urihttps://doi.org/10.4274/tjo.37267
dc.identifier.urihttps://hdl.handle.net/20.500.12452/16457
dc.identifier.volume44en_US
dc.identifier.wosWOS:000219228300004en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isotren_US
dc.publisherTurkish Ophthalmological Socen_US
dc.relation.ispartofTurk Oftalmoloji Dergisi-Turkish Journal Of Ophthalmologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCorneaen_US
dc.subjectEye Rubbingen_US
dc.subjectOcular Response Analyzeren_US
dc.titleEffect of Eye Rubbing on Corneal Biomechanical Properties and Intraocular Pressureen_US
dc.typeArticleen_US

Dosyalar