An Electrochemical Acetylcholinesterase Biosensor Based on Fluorene(bisthiophene) Comprising Polymer for Paraoxon Detection
| dc.contributor.author | Celik, Huzeyfe | |
| dc.contributor.author | Soylemez, Saniye | |
| dc.date.accessioned | 2024-02-23T12:06:43Z | |
| dc.date.available | 2024-02-23T12:06:43Z | |
| dc.date.issued | 2023 | |
| dc.department | NEÜ | en_US |
| dc.description.abstract | In this study, a novel conductive polymer comprising biosensor based on poly-2,2 '-(9,9-dioctyl-9 h-fluorene-2,7-diyl)bistiophene (Poly(BT)) and acetylcholinesterase (AChE) was reported for the determination of paraoxon. This practical biosensor allowed to catalyze electrochemical oxidation of acetylthiocholine (+0.6 V vs. Ag reference). The detection range for acetylcholine chloride (AThCl) with Poly(BT)/AChE was found to be 0.025-4 mM. In pesticide analysis, wide linear ranges from 0.5 to 1 mu g/L and 1 to 14 mu g/L, and a low detection limit of 0.033 mu g/L were estimated. Under optimum operating conditions, the developed biosensor was used for pesticide detection in milk and tap water samples, effectively. | en_US |
| dc.description.sponsorship | Ordu University BAP project [B-2111] | en_US |
| dc.description.sponsorship | The authors acknowledge support from Ordu University BAP project (Project No. B-2111). | en_US |
| dc.identifier.doi | 10.1002/elan.202200271 | |
| dc.identifier.issn | 1040-0397 | |
| dc.identifier.issn | 1521-4109 | |
| dc.identifier.issue | 3 | en_US |
| dc.identifier.scopus | 2-s2.0-85137348329 | en_US |
| dc.identifier.scopusquality | Q2 | en_US |
| dc.identifier.uri | https://doi.org/10.1002/elan.202200271 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12452/10558 | |
| dc.identifier.volume | 35 | en_US |
| dc.identifier.wos | WOS:000849808200001 | en_US |
| dc.identifier.wosquality | Q2 | en_US |
| dc.indekslendigikaynak | Web of Science | en_US |
| dc.indekslendigikaynak | Scopus | en_US |
| dc.language.iso | en | en_US |
| dc.publisher | Wiley-V C H Verlag Gmbh | en_US |
| dc.relation.ispartof | Electroanalysis | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.subject | Electrochemical Biosensor | en_US |
| dc.subject | Conjugated Polymer | en_US |
| dc.subject | Acetylcholinesterase | en_US |
| dc.subject | Enzyme Immobilization | en_US |
| dc.subject | Organophosphorus Pesticides | en_US |
| dc.title | An Electrochemical Acetylcholinesterase Biosensor Based on Fluorene(bisthiophene) Comprising Polymer for Paraoxon Detection | en_US |
| dc.type | Article | en_US |












