Low velocity impact response and damages of GFRP composite tubes under room and cryogenic temperatures

Küçük Resim Yok

Tarih

2021

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Sage Publications Ltd

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

In this paper, we have investigated the damages of glass fiber reinforced plastic (GFRP) composite tubes under the effect of low-velocity impact (LVI) at cryogenic environment conditions and room temperature. A GFRP composite tube consists of 6 layered E-glass/epoxy samples with a +/- 55 degrees winding angle, which produced by the filament winding method. Composite tubes either at room temperature or conditioned by liquid nitrogen at different temperature values (273 K, 223 K, 173 K, and 77 K) were impacted at 5, 7.5, and 10 J. Also, force-time and force-displacement graphs were plotted. The damaged regions of the samples were scrutinized. The damage areas of the GFRP composite tubes were smaller as the temperature decreased. However, the energy absorbed at low-temperature conditions was slightly higher than that absorbed in room temperature. Besides, no micro-cracks developed in the composite tubes after cryogenic conditioning.

Açıklama

Anahtar Kelimeler

Glass-Fiber Reinforced Plastic, Filament Winding, Cryogenic, Low-Velocity Impact, Damage

Kaynak

Journal Of Composite Materials

WoS Q Değeri

Q3