A chemometric study: Automated flow injection analysis method for the quantitative determination of humic acid in Ilgm lignite

dc.contributor.authorTarhan, Ismail
dc.contributor.authorKara, Huseyin
dc.date.accessioned2024-02-23T14:02:08Z
dc.date.available2024-02-23T14:02:08Z
dc.date.issued2016
dc.departmentNEÜen_US
dc.description.abstractA rapid, sensitive and provident flow injection analysis (FIA) method was developed within the framework of a chemometric approach for the quantification of humic acid (HA) in the lignite obtained from Ilgm, Konya, Turkey. The proposed method allows automatic determination of 60 samples per hour over a wide calibration range (0-2000 mg L-1, R-2: 0.9988) and needs only 10 mu L of sample at a flow rate of mobile phase (X-1), 2 mL min(-1); pH of mobile phase (X-2), 8, and system temperature (X-3), 20 degrees C. The limits of detection (LOD) and quantification (LOQ) were calculated as 9.18 mg L-1 and 30.60 mg L-1, respectively, and the relative standard deviation (RSD) for 500 mg L-1 HA was calculated as 3.44 (n: 9). It was revealed that the standard deviation (SD) values of the proposed FIA method are lower than those of the spectrophotometric method. (C) 2014 King Saud University. Production and hosting by Elsevier B.V.en_US
dc.description.sponsorshipScientific Research Projects Foundation of Selcuk University (SUBAP) [11101002]; TUBITAK [TUBITAK 2221]en_US
dc.description.sponsorshipThe authors of this study thank the Scientific Research Projects Foundation of Selcuk University (SUBAP-Grant Number 11101002) for financial support of this work produced from a part of Ismail Tarhan's MsC Thesis. The authors would also like to thank TUBITAK for providing financial support to one of our research collaborator Professor Dr. S.T.H. Sherazi under TUBITAK 2221 Fellowship for Visiting Scientists and Scientists on Sabbatical Leave program.en_US
dc.identifier.doi10.1016/j.arabjc.2014.09.002
dc.identifier.endpage720en_US
dc.identifier.issn1878-5352
dc.identifier.issn1878-5379
dc.identifier.issue5en_US
dc.identifier.scopus2-s2.0-84908539733en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage713en_US
dc.identifier.urihttps://doi.org/10.1016/j.arabjc.2014.09.002
dc.identifier.urihttps://hdl.handle.net/20.500.12452/11600
dc.identifier.volume9en_US
dc.identifier.wosWOS:000383114700014en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherElsevier Science Bven_US
dc.relation.ispartofArabian Journal Of Chemistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectChemometryen_US
dc.subjectFlow Injection Analysisen_US
dc.subjectHumic Aciden_US
dc.subjectLigniteen_US
dc.titleA chemometric study: Automated flow injection analysis method for the quantitative determination of humic acid in Ilgm ligniteen_US
dc.typeArticleen_US

Dosyalar