Bag-Valve-Mask versus Laryngeal Mask Airway Ventilation in Cardiopulmonary Resuscitation with Continuous Compressions: A Simulation Study

Küçük Resim Yok

Tarih

2021

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Cambridge Univ Press

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

Introduction: The 2017 International Liaison Committee on Resuscitation (ILCOR) guideline recommends that Emergency Medical Service (EMS) providers can perform cardiopulmonary resuscitation (CPR) with synchronous or asynchronous ventilation until an advanced airway has been placed. In the current literature, limited data on CPR performed with continuous compressions and asynchronous ventilation with bag-valve-mask (BVM) are available. Study Objective: In this study, researchers aimed to compare the effectiveness of asynchronous BVM and laryngeal mask airway (LMA) ventilation during CPR with continuous chest compressions. Methods: Emergency medicine residents and interns were included in the study. The participants were randomly assigned to resuscitation teams with two rescuers. The cross-over simulation study was conducted on two CPR scenarios: asynchronous ventilation via BVM during a continuous chest compression and asynchronous ventilation via LMA during a continuous chest compression in cardiac arrest patient with asystole. The primary endpoints were the ventilation-related measurements. Results: A total of 92 volunteers were included in the study and 46 CPRs were performed in each group. The mean rate of ventilations of the LMA group was significantly higher than that of the BVM group (13.7 [11.7-15.7] versus 8.9 [7.5-10.3] breaths/minute; P <.001). The mean volume of ventilations of the LMA group was significantly higher than that of the BVM group (358.4 [342.3-374.4] ml versus 321.5 [303.9-339.0] ml; P = .002). The mean minute ventilation volume of the LMA group was significantly higher than that of the BVM group (4.88 [4.15-5.61] versus 2.99 [2.41-3.57] L/minute; P <.001). Ventilations exceeding the maximum volume limit occurred in two (4.3%) CPRs in the BVM group and in 11 (23.9%) CPRs in the LMA group (P = .008). Conclusion: The results of this study show that asynchronous BVM ventilation with continuous chest compressions is a reliable and effective strategy during CPR under simulation conditions. The clinical impact of these findings in actual cardiac arrest patients should be evaluated with further studies at real-life scenes.

Açıklama

Anahtar Kelimeler

Bag-Valve-Mask, Cardiopulmonary Resuscitation, Continuous Compression, Laryngeal Mask Airway, Ventilation

Kaynak

Prehospital And Disaster Medicine

WoS Q Değeri

Q2

Scopus Q Değeri

Q2

Cilt

36

Sayı

2

Künye