Investigation of Performance of Heating and Cooling of Counter Flow Ranque-Hilsch Tubes with L/D=15, 16, 17, 18 for Brass

Küçük Resim Yok

Tarih

2013

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Trans Tech Publications Ltd

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

In this study, heating and cooling performances of counter flow Ranque-Hilsch vortex tubes (RHVTs) were experimentally investigated for brass. The vortex tubes were made of brass. Diameter of vortex tube (D) was 10 mm. Length of vortex tube (L) was 15D, 16D, 17D and18D. The number of nozzles (Nn) was 5. The conical edges of the plugs have a slope of 30 degrees angle. Working pressure of Ranque-Hilsch was 460 kPa (absolute). According to the experimental results, the maximum heating performance of the RHVT system was found to be 39,5 degrees C at P-17 and the maximum cooling performance of the RHVT in this study was found to be -28,6 degrees C at P-18. An increase in fraction of cold flow (xi) led to a increase in the heating performance.

Açıklama

2nd International Conference on Advanced Materials Design and Mechanics (ICAMDM 2013) -- MAY 17-18, 2013 -- Kuala Lumpur, MALAYSIA

Anahtar Kelimeler

Ranque-Hilsch Vortex Tube, Heating, Cooling, Temperature Separation