HPLC analysis of eluted monomers released from dental composites containing bioactive glass

dc.contributor.authorGezgin, Onur
dc.contributor.authorKorkut, Emre
dc.contributor.authorTulumbaci, Fatih
dc.contributor.authorOzer, Hazal
dc.contributor.authorSener, Yagmur
dc.date.accessioned2024-02-23T14:17:15Z
dc.date.available2024-02-23T14:17:15Z
dc.date.issued2018
dc.departmentNEÜen_US
dc.description.abstractObjectives: The aim of the present study is to evaluate the released residual monomers from composite resins that contain different proportions of bioactive glass (BAG). Methods: Experimental resin composites were prepared by a resin matrix (50% BisGMA and 50% TEGDMA) and inorganic filler with BAG (5, 10 and 30%). Each resin composite was placed in the tooth cavity (n=5). After polymerisation, samples were immediately immersed in 75% ethanol and 25% deionised water (6ml) at 37 degrees C. Residual monomers (Bis-GMA, TEGDMA, HEMA and UDMA) that were eluted from the composites for 10m, 1h, 1 d, 7 d and 30 d were analysed by high-performance liquid chromatography (HPLC). The data were analysed with one-way ANOVA and Tukey HSD at a p<0.05 significance level. Results: Among the time periods, the fastest released residual monomer was observed in the 10m elution. The highest amount of released residual monomer from all groups (except the control group) was TEGDMA, whereas this was HEMA for the control group. The amounts of residual monomers eluted from BAG30 were significantly higher than other groups (p<0.05). Conclusions: The release of the monomer increases in accordance with the increased BAG addition to the composite resins.en_US
dc.identifier.doi10.1080/01694243.2018.1440815
dc.identifier.endpage1731en_US
dc.identifier.issn0169-4243
dc.identifier.issn1568-5616
dc.identifier.issue15en_US
dc.identifier.scopus2-s2.0-85042209898en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage1724en_US
dc.identifier.urihttps://doi.org/10.1080/01694243.2018.1440815
dc.identifier.urihttps://hdl.handle.net/20.500.12452/13022
dc.identifier.volume32en_US
dc.identifier.wosWOS:000428815700009en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherTaylor & Francis Ltden_US
dc.relation.ispartofJournal Of Adhesion Science And Technologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBioactive Glassen_US
dc.subjectElutionen_US
dc.subjectHplcen_US
dc.subjectMonomer Releaseen_US
dc.subjectResin Compositesen_US
dc.titleHPLC analysis of eluted monomers released from dental composites containing bioactive glassen_US
dc.typeArticleen_US

Dosyalar