Evaluation of temperature changes in the pulp chamber during polymerization of pulp capping materials

dc.contributor.authorKorkut, Emre
dc.contributor.authorTulumbaci, Fatih
dc.contributor.authorGezgin, Onur
dc.contributor.authorOzer, Hazal
dc.contributor.authorOzcan, Mutlu
dc.date.accessioned2024-02-23T14:17:16Z
dc.date.available2024-02-23T14:17:16Z
dc.date.issued2018
dc.departmentNEÜen_US
dc.description.abstractPolymerization of resin-based materials leads to temperature rise, caused by the exothermic nature of the reaction and energy absorbed during polymerization. This temperature rise is influenced by intensity of light, composition of resins, and type of light source. This study evaluated thermal insulating properties of four photo-polymerizing pulp-capping agents in primary and permanent teeth. Roots of 80 primary and permanent teeth were removed. Class-I cavities were prepared on the occlusal surfaces of teeth. Materials used were TheraCal LC, Biner LC, ACTIVA BioACTIVE, and Calciplus LC and light sources were 3M-Elipar and VALO LED. Temperature rise was measured using a J-type thermocouple. Data were statistically evaluated using ANOVA and Tukey`s tests (p=0.05). VALO LED exhibited significantly lower temperature rise in all groups and temperature rise in primary teeth was significantly higher with all experimental materials (p<0.05). The highest temperature change was observed in the Biner LC group (3.82 +/- 0.58) and the lowest change in the Activa-BioACTIVE group (1.78 +/- 0.34). The VALO LED light source caused a significantly lower increase in pulpal temperature compared with the 3M-Elipar source. All tested materials and light sources maintained pulpal temperature under safe limits, with temperature increases not exceeding 5.5 degrees C.en_US
dc.identifier.doi10.1080/01694243.2018.1472427
dc.identifier.endpage2253en_US
dc.identifier.issn0169-4243
dc.identifier.issn1568-5616
dc.identifier.issue20en_US
dc.identifier.scopus2-s2.0-85047165340en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage2244en_US
dc.identifier.urihttps://doi.org/10.1080/01694243.2018.1472427
dc.identifier.urihttps://hdl.handle.net/20.500.12452/13023
dc.identifier.volume32en_US
dc.identifier.wosWOS:000445077400005en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherTaylor & Francis Ltden_US
dc.relation.ispartofJournal Of Adhesion Science And Technologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDental Cavity Lineren_US
dc.subjectDental Curing Lightsen_US
dc.subjectPulp Cappingen_US
dc.subjectPrimary Teethen_US
dc.subjectTemperatureen_US
dc.titleEvaluation of temperature changes in the pulp chamber during polymerization of pulp capping materialsen_US
dc.typeArticleen_US

Dosyalar