Comparison of apical debris extrusion Using EDDY, passive ultrasonic activation and photon-initiated photoacoustic streaming irrigation activation devices

dc.contributor.authorInce Yusufoglu, Selen
dc.contributor.authorKeskin, Neslihan Busra
dc.contributor.authorSaricam, Esma
dc.contributor.authorBozkurt, Durmus Alperen
dc.date.accessioned2024-02-23T14:24:00Z
dc.date.available2024-02-23T14:24:00Z
dc.date.issued2020
dc.departmentNEÜen_US
dc.description.abstractThe study aimed to determine the effect of different irrigation activation systems on the amount of apical debris extrusion in mandibular molar teeth with curved root canals. Sixty extracted mandibular molar teeth were instrumented with HyFlex EDM system and divided into four groups according to irrigation techniques: passive ultrasonic irrigation (PUI), EDDY, photon-initiated photoacoustic streaming (PIPS) and manual irrigation (MI). After the final irrigation, the extruded irrigants were collected into Eppendorf tubes of known weights. The amount of extruded debris was obtained by subtracting the weight from the initial weight of the tube. The Kruskal-Wallis test was used for statistical analysis. EDDY caused significantly more debris extrusion than the other irrigation activation systems (P < 0.001). PUI caused less apical debris extrusion but there was no statistical difference between PUI, PIPS and MI (P > 0.05). The EDDY activation system was associated with the highest amount of debris extrusion in curved root canals.en_US
dc.identifier.doi10.1111/aej.12429
dc.identifier.endpage404en_US
dc.identifier.issn1329-1947
dc.identifier.issn1747-4477
dc.identifier.issue3en_US
dc.identifier.pmid32881182en_US
dc.identifier.scopus2-s2.0-85090120528en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage400en_US
dc.identifier.urihttps://doi.org/10.1111/aej.12429
dc.identifier.urihttps://hdl.handle.net/20.500.12452/13770
dc.identifier.volume46en_US
dc.identifier.wosWOS:000565420200001en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherWileyen_US
dc.relation.ispartofAustralian Endodontic Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectDebris Extrusionen_US
dc.subjectEddyen_US
dc.subjectIrrigation Activationen_US
dc.subjectPassive Ultrasonic Activationen_US
dc.subjectPipsen_US
dc.titleComparison of apical debris extrusion Using EDDY, passive ultrasonic activation and photon-initiated photoacoustic streaming irrigation activation devicesen_US
dc.typeArticleen_US

Dosyalar