The Investigation of the Marginal Microleakage of Ceramic Veneer Crowns with Different Finish Lines
| dc.contributor.author | Akin, Ceyda | |
| dc.contributor.author | Inan, Ozgur | |
| dc.date.accessioned | 2024-02-23T14:38:11Z | |
| dc.date.available | 2024-02-23T14:38:11Z | |
| dc.date.issued | 2022 | |
| dc.department | NEÜ | en_US |
| dc.description.abstract | Objective: This study aimed to evaluate the microleakage of lithium disilicate and zirconium dioxide all ceramic crowns. Materials and Methods: A total of 80 premolar teeth with two different marginal finish lines were divided into 2 groups to produce zirconia and lithium disilicate crowns. The crowns were cemented by two different cements (n=10). Samples were stained with 0.5% basic fuchsin solution and the dye penetration was scored. Statistical comparisons were made using two-way ANOVA and two-sample t-test. Results: There were no statistically significant differences in preparation types (p>0.05). However, ceramic systems and cement types for the microleakage test Conclusion: The use of self-adhesive cement is recommended for lithium disilicate restoration to minimize marginal microleakage. | en_US |
| dc.description.sponsorship | Scientific Research Project Council of Sel?uk University, Turkey [12202020] | en_US |
| dc.description.sponsorship | Financial Disclosure: This scientific research was supported by the Scientific Research Project Council of Sel?uk University, Turkey (project no: 12202020) . | en_US |
| dc.identifier.doi | 10.4274/meandros.galenos.2022.51422 | |
| dc.identifier.endpage | 494 | en_US |
| dc.identifier.issn | 2149-9063 | |
| dc.identifier.issue | 4 | en_US |
| dc.identifier.startpage | 488 | en_US |
| dc.identifier.uri | https://doi.org/10.4274/meandros.galenos.2022.51422 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12452/16415 | |
| dc.identifier.volume | 23 | en_US |
| dc.identifier.wos | WOS:000917548600012 | en_US |
| dc.indekslendigikaynak | Web of Science | en_US |
| dc.language.iso | en | en_US |
| dc.publisher | Galenos Publ House | en_US |
| dc.relation.ispartof | Meandros Medical And Dental Journal | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/openAccess | en_US |
| dc.subject | Microleakage | en_US |
| dc.subject | All-Ceramic | en_US |
| dc.subject | Marginal Finish Line | en_US |
| dc.title | The Investigation of the Marginal Microleakage of Ceramic Veneer Crowns with Different Finish Lines | en_US |
| dc.type | Article | en_US |












