Electrochemical determination of copper(II) ions at naringenin-modified glassy carbon electrode: application in lake water sample

dc.contributor.authorMulazimoglu, Ibrahim Ender
dc.date.accessioned2024-02-23T14:40:52Z
dc.date.available2024-02-23T14:40:52Z
dc.date.issued2012
dc.departmentNEÜen_US
dc.description.abstractElectrochemical modification of glassy carbon (GC) electrode by naringenin (NG), a flavonoid derivative, and applicability of electrode modified in this way for determination of copper(II) (Cu(II)) ions is reported in this study. Surface modification experiments were performed in phosphate buffer solution (PBS), pH 7, in the 0.0 mV and +1400 mV potential ranges with a sweep rate of 100 mV s(-1) and 30 cycles. The surface modification of GC electrode was performed with NG using cyclic voltammetry (CV), whereas the characterization of this sensor electrode was performed using CV and electrochemical impedance spectroscopy (EIS). The sensitivity of GC electrode modified in described way towards Cu(II) ions was investigated in Britton-Robinson (BR) buffer solution, pH 5, by differential pulse voltammetry (DPV). For the calibration curve, a series of standard Cu(II) solution from 1.0 x 10(-12) M to 1.0 x 10(-6) M was prepared. The NG modified GC (NG/GC) sensor electrode, has a good repeatability, was applied for Cu(II) ions determination in Beysehir lake (in Konya, Turkey) water sample. Detection limit was obtained as lower as 1.0 x 10(-12) M. The proposed method was simple, rapid, low cost and sensitive for the determination of Cu(II) ions.en_US
dc.description.sponsorshipResearch Foundation of Selcuk University, Konya-TURKEY [BAP-09401118]en_US
dc.description.sponsorshipThis study was financially supported by the Research Foundation of Selcuk University, Konya-TURKEY (BAP-09401118).en_US
dc.identifier.doi10.5004/dwt.2012.2994
dc.identifier.endpage167en_US
dc.identifier.issn1944-3994
dc.identifier.issn1944-3986
dc.identifier.issue1.Maren_US
dc.identifier.scopusqualityQ3en_US
dc.identifier.startpage161en_US
dc.identifier.urihttps://doi.org/10.5004/dwt.2012.2994
dc.identifier.urihttps://hdl.handle.net/20.500.12452/16624
dc.identifier.volume44en_US
dc.identifier.wosWOS:000304589200019en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.language.isoenen_US
dc.publisherDesalination Publen_US
dc.relation.ispartofDesalination And Water Treatmenten_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectFlavonoiden_US
dc.subjectCu(Ii) Ionsen_US
dc.subjectSurface Modificationen_US
dc.subjectSurface Characterizationen_US
dc.subjectDifferential Pulse Voltammetryen_US
dc.subjectCyclic Voltammetryen_US
dc.titleElectrochemical determination of copper(II) ions at naringenin-modified glassy carbon electrode: application in lake water sampleen_US
dc.typeArticleen_US

Dosyalar