A reduced graphene oxide/?-cyclodextrin hybrid for the detection of methionine: electrochemical, fluorometric and computational studies
dc.contributor.author | Zor, Erhan | |
dc.contributor.author | Saglam, Muhammed Esad | |
dc.contributor.author | Alpaydin, Sabri | |
dc.contributor.author | Bingol, Haluk | |
dc.date.accessioned | 2024-02-23T14:16:45Z | |
dc.date.available | 2024-02-23T14:16:45Z | |
dc.date.issued | 2014 | |
dc.department | NEÜ | en_US |
dc.description.abstract | We report on fluorometric and voltammetric detection of L-methionine (Met) based on host-guest interactions between Met and reduced graphene oxide/alpha-cyclodextrin (rGO/alpha-CD) hybrid materials. For voltammetric measurements, rGO/alpha-CD was used as an electrode modification material and successful detection of Met was achieved. Also, rGO/alpha-CD was used as a fluorescence quencher (turn off) for luminol which was employed as a fluorescent probe. The addition of Met into the same solution gave rise to fluorescence enhancement (turn on) after the host-guest recognition between Met and rGO/alpha-CD which caused the release of luminol. Interactions of luminol and Met with rGO/alpha-CD were modeled by molecular docking using AutoDock Vina and the interaction energies were predicted to be -4.3 and -4.4 kcal mol(-1), respectively. The proposed biosensor is considered to be a promising model for the detection of Met. | en_US |
dc.description.sponsorship | Necmettin Erbakan University [121210004/122010005] | en_US |
dc.description.sponsorship | The authors are grateful to the Scientific Research Projects of Necmettin Erbakan University (121210004/122010005) for the financial support. | en_US |
dc.identifier.doi | 10.1039/c4ay00984c | |
dc.identifier.endpage | 6530 | en_US |
dc.identifier.issn | 1759-9660 | |
dc.identifier.issn | 1759-9679 | |
dc.identifier.issue | 16 | en_US |
dc.identifier.scopus | 2-s2.0-84905191698 | en_US |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.startpage | 6522 | en_US |
dc.identifier.uri | https://doi.org/10.1039/c4ay00984c | |
dc.identifier.uri | https://hdl.handle.net/20.500.12452/12777 | |
dc.identifier.volume | 6 | en_US |
dc.identifier.wos | WOS:000340320300045 | en_US |
dc.identifier.wosquality | Q2 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Royal Soc Chemistry | en_US |
dc.relation.ispartof | Analytical Methods | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | [Keyword Not Available] | en_US |
dc.title | A reduced graphene oxide/?-cyclodextrin hybrid for the detection of methionine: electrochemical, fluorometric and computational studies | en_US |
dc.type | Article | en_US |