Yazar "Memon, Ayaz A." seçeneğine göre listele
Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Copper sorption efficiency of p-tetranitrocalix[4]arene based high performance liquid chromatographic column(Desalination Publ, 2016) Durmaz, Fatih; Memon, Fakhar N.; Memon, Shahabuddin; Memon, Ayaz A.; Memon, Naeem A.; Kara, HuseyinPresent study deals with the sorption characteristics of p-tetranitrocalix[4]arene (3) appended silica-based high-performance liquid chromatographic (HPLC) column utilized for preconcentration, determination, and purification of Cu2+ from water. The sorption characteristics of the HPLC column were investigated for Cu2+ in column agreement. The experiments were performed in five steps that were monitored using UV-visible diode-array detector. However, all the HPLC experimental results were reconfirmed by using atomic absorption spectrophotometer. The effect of concentration on the sorption efficiency of the column was evaluated for Cu2+ and data obtained was investigated using Langmuir and Freundlich sorption isotherms. The value of coefficient of determination (R-2), i.e. 0.99, suggested that the Freundlich sorption isotherm was found to be the best fit model for Cu2+. The developed method was validated for system efficiency, accuracy, and precision, while the data obtained revealed that the developed column could be applied for the sorption of Cu2+ with adequate efficiency and repeatability.Öğe Simultaneous determination of some basic dyes using p-tetranitrocalix[4]arene-appended silica-based HPLC column(Royal Soc Chemistry, 2014) Memon, Shahabuddin; Memon, Fakhar N.; Durmaz, Fatih; Memon, Naeem A.; Memon, Ayaz A.; Kara, HuseyinThis study focuses on the synthesis, characterization and application of p-tetranitrocalix[4]arene-appended silica-based material as a stationary phase in high-performance liquid chromatography for the simultaneous separation of some basic dyes such as methyl violet, methyl green and methylene blue. The effect of the pH of mobile phase on the retention, separation and selectivity of these compounds was investigated. The method was validated for system efficiency, linearity, accuracy, precision, limit of detection and quantification. The limits of detection were 0.1, 0.5 and 0.3 mg L-1; whereas, the limits of quantification were observed to be 1, 1.2 and 0.9 mg L-1 for methyl violet, methyl green and methylene blue, respectively. The separation efficiency of the p-tetranitrocalix[4]arene-appended silica-based column was also compared to that of the octadecylsilane column.