Reduced Graphene Oxide/α‐Cyclodextrin‐Based Electrochemical Sensor: Characterization and Simultaneous Detection of Adenine, Guanine and Thymine

dc.authoridErhan Zor: 0000-0002-2325-6354
dc.contributor.authorZor, Erhan
dc.date.accessioned2020-01-18T21:11:18Z
dc.date.available2020-01-18T21:11:18Z
dc.date.issued2017
dc.departmentNEÜ, Ahmet Keleşoğlu Eğitim Fakültesi, Matematik ve Fen Bilimleri Eğitimi Bölümüen_US
dc.description.abstractGraphene, the rising star of carbon nanomaterials, is a single layer of sp2‐bonded carbon atoms patterned in a 2D honeycomb network. Thanks to its unique features, graphene has attracted enormous attention and it has arisen various applications in the fields of optical and electrochemical sensors. In the present work, reduced graphene oxide/alpha cyclodextrin (rGO/α‐CD) is proposed as a nanocomposite for individual and simultaneous detection of adenine, guanine and thymine. rGO/α‐CD has been characterized by FT‐IR, Raman spectroscopy, AFM, HR‐TEM and SEM techniques. Cyclic voltammetry, differential pulse voltammetry and chronoamperometry techniques were utilized for detection of adenine, guanine and thymine. The limit of detection (LOD) values for adenine, guanine and thymine were calculated to be 145.5, 38.9 and 52.9 nmol L‐1, respectively. The results show that the developed sensor can be utilized for the determination of adenine, guanine and thymine in human serum, indicating its promising application in the analysis of real samples.en_US
dc.description.abstractKarbon nano materyallerin yükselen yıldızı olan grafen, sp2‐hibritleşmesi yapmış ve iki boyutlu bal peteği şeklinde düzenlenmiş olan karbon atomlarının bir atom kalınlığında oluşturduğu tabakadır. Benzersiz özellikleri sayesinde, grafen büyük ilgi uyandırmış olup optik ve elektrokimyasal sensörler alanında çok çeşitli uygulama alanlarının gelişmesine katkı sağlamıştır. Bu çalışmada, adenin, guanin ve timinin tek başına ve eş zamanlı tayinlerini gerçekleştirebilmek için indirgenmiş grafen oksit/alfa siklodekstrin (rGO/α‐CD) nano kompozit malzemesi önerilmektedir. rGO/α‐CD materyali FT‐IR, Raman spektroskopisi, AFM, HR‐TEM ve SEM teknikleri ile karakterize edilmiştir. Adenin, guanin ve timin tayini için dönüşümlü voltametri, diferansiyel puls voltametrisi ve kronoamperometri teknikleri kullanılmıştır. Adenin, guanin ve timin için en düşük tayin limitleri 145.5, 38.9 ve 52.9 nmol L‐1 olarak hesaplanmıştır. Çalışma sonuçları, önerilen bu sensörün adenin, guanin ve timinin insan serumu içerisinde tayin edilebileceğini ve dolayısıyla gerçek numune analizinde umut vadeden bir uygulama olduğunu göstermiştir.en_US
dc.identifier.citationZor, E. (2017). Reduced graphene oxide/α‐cyclodextrin‐based electrochemical sensor: Characterization and simultaneous detection of adenine, guanine and thymine. Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi, 21, 1, 146-152.en_US
dc.identifier.doi10.19113/sdufbed.72272en_US
dc.identifier.endpage152en_US
dc.identifier.issn1300-7688en_US
dc.identifier.issn1308-6529en_US
dc.identifier.issue1en_US
dc.identifier.startpage146en_US
dc.identifier.urihttps://dx.doi.org/10.19113/sdufbed.72272
dc.identifier.urihttps://app.trdizin.gov.tr/makale/TWpnM01qSXdNQT09/reduced-graphene-oxide-cyclodextrin-based-electrochemical-sensor-characterization-and-simultaneous-detection-of-adenine-guanine-and-thymine
dc.identifier.urihttps://hdl.handle.net/20.500.12452/2418
dc.identifier.volume21en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.language.isoenen_US
dc.relation.ispartofSüleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisien_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US]
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectGraphene oxide
dc.subjectCyclodextrin
dc.subjectElectrochemical sensor
dc.subjectAdenine
dc.subjectGuanine
dc.subjectThymine
dc.subjectGrafen oksit
dc.subjectSiklodekstrin
dc.subjectElektrokimyasal sensör
dc.subjectAdenin
dc.subjectGuanin
dc.subjectTimin
dc.titleReduced Graphene Oxide/α‐Cyclodextrin‐Based Electrochemical Sensor: Characterization and Simultaneous Detection of Adenine, Guanine and Thymineen_US
dc.title.alternativeİndirgenmiş Grafen Oksit/α‐Siklodekstrin Esaslı Elektrokimyasal Sensör: Karakterizasyon ve Adenin, Guanin ve Timinin Eşzamanlı Tayinien_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Reduced Graphene Oxide Cyclodextrin Based Electrochemical Sensor Characterization and Simultaneous Detection of Adenine, Guanine and Thymine.pdf
Boyut:
494.72 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin (Full Text)