Dekstransız İzotonik Riboflavin Solüsyonu ile Yapılan Kornea Kollajen Çapraz Bağlama Uygulaması Sırasında Kornea Kalınlığı
dc.authorid | Refik Oltulu: 0000-0003-2447-6524 | |
dc.authorid | Günhal Şatırtav Akdeniz : 0000-0003-4157-2876 | |
dc.authorid | Ahmet Özkağnıcı: 0000-0001-7411-2484 | |
dc.contributor.author | Oltulu, Refik | |
dc.contributor.author | Donbaloğlu, Meryem | |
dc.contributor.author | Şatırtav Akdeniz, Günhal | |
dc.contributor.author | Zengin, Nazmi | |
dc.contributor.author | Özkağnıcı, Ahmet | |
dc.date.accessioned | 2020-01-18T21:03:49Z | |
dc.date.available | 2020-01-18T21:03:49Z | |
dc.date.issued | 2014 | |
dc.department | NEÜ, Meram Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Göz Hastalıkları Anabilim Dalı | en_US |
dc.description.abstract | Amaç: Dekstransız izotonik riboflavin solüsyonu ile yapılan kornea kollajen çapraz bağlama (KKÇB) uygulamasında kornea kalınlığının takip edilmesi. Gereç ve Yöntem: Progresif keratokonus olgularına uygulanan KKÇB uygulaması sırasında kornea kalınlığı değerlendirildi. Her olgunun sırası ile kornea epiteli kazındıktan sonra: 0., 15. ve 30. dakikalarda, Ultraviole A (UVA) uygulama sırasında 15. ve 30. dakikalarda santral kornea kalınlığı ultrasonik pakimetri cihazı ile ölçüldü. Bulgular: Progresif keratokonusu olan 24 olgunun 24 gözü çalışmaya dahil edildi. Ortalama en ince pakimetrik değer, kornea epiteli kazındıktan sonra 0., 15. ve 30. dakikalarda sırasıyla 409,3810,43 ?m (383-435 ?m), 434,5617,68 ?m (400-485 ?m) ve 457,4421,78 ?m (428-516 ?m) idi ve UVA uygulamasının 15. ve 30. dakikasında sırasıyla 471,6923,38 ?m (439-526 ?m) ve 482,6323,69 ?m (436-524 ?m) olarak tespit edildi. Uygulama süresince kornea kalınlığındaki artışın bir önceki ölçümle kıyaslandığında istatistiksel olarak anlamlı olduğu görüldü (p0,001). Sonuç: Dekstransız izotonik riboflavin solüsyonu ile yapılan KKÇB uygulaması sırasında korneada incelmenin olmadığı, aksine uygulama süresince korneanın düzenli şekilde kalınlaştığı görüldü. (Turk J Ophthalmol 2014; 44: 272-4) | en_US |
dc.description.abstract | Objectives: To monitor the corneal thickness change during the dextran-free isotonic riboflavin solution-aided corneal collagen cross-linking procedure in keratoconus patients. Materials and Methods: Corneal thickness measurements during the corneal collagen cross-linking (CXL) treatment for progressive keratoconus were evaluated. The corneal thickness measurements were obtained with ultrasonic pachymetry device at five different time points: 0, 15, and 30 minutes after epithelial removal and 15 and 30 minutes after the initiation of UVA irradiation. Results: Twenty-four eyes of 24 patients with progressive keratoconus were included in the study. The thinnest pachymetric values obtained at the 0, 15, and 30 minute measurements after corneal deepithelisation were 409.3810.43 ?m (383-435 ?m), 434.5617.68 ?m (400-485 ?m), and 457.4421.78 ?m (428-516 ?m), respectively. Pachymetric values obtained at 15 and 30 minutes after UVA application to the cornea were 471.6923.38 ?m (439-526 ?m) and 482.6323.69 ?m (436-524 ?m), respectively. The gradual increase was found to be statistically significant when each measurement was compared with the previous values (p0.001). Conclusion: We found that the corneal thickness was not decreased during the CXL with dextran-free isotonic riboflavin solution; on the contrary, corneal thickness was increased regularly during the procedure. (Turk J Ophthalmol 2014; 44: 272-4) | en_US |
dc.identifier.citation | Oltulu, R., Donbaloğlu, M., Şatırtav Akdeniz, G., Zengin, N., Özkağnıcı, A. (2014). Dekstransız izotonik riboflavin solüsyonu ile yapılan kornea kollajen çapraz bağlama uygulaması sırasında kornea kalınlığı. Türk Oftalmoloji Dergisi, 44, 4, 272-274. | |
dc.identifier.endpage | 274 | en_US |
dc.identifier.issn | 1300-0659 | en_US |
dc.identifier.issn | 2147-2661 | en_US |
dc.identifier.issue | 4 | en_US |
dc.identifier.startpage | 272 | en_US |
dc.identifier.uri | https://app.trdizin.gov.tr/makale/TVRZek5qRTFOUT09/dekstransiz-izotonik-riboflavin-solusyonu-ile-yapilan-kornea-kollajen-capraz-baglama-uygulamasi-sirasinda-kornea-kalinligi | |
dc.identifier.uri | https://hdl.handle.net/20.500.12452/1688 | |
dc.identifier.volume | 44 | en_US |
dc.indekslendigikaynak | TR-Dizin | en_US |
dc.language.iso | tr | en_US |
dc.relation.ispartof | Türk Oftalmoloji Dergisi | en_US |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı | en_US] |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Keratokonus | en_US |
dc.subject | Kollajen çapraz bağlama | en_US |
dc.subject | Kornea kalınlığı | en_US |
dc.subject | Keratoconus | en_US |
dc.subject | Collagen cross-linking | en_US |
dc.subject | Corneal thickness | en_US |
dc.title | Dekstransız İzotonik Riboflavin Solüsyonu ile Yapılan Kornea Kollajen Çapraz Bağlama Uygulaması Sırasında Kornea Kalınlığı | en_US |
dc.title.alternative | Corneal Thickness During Corneal Collagen Cross-Linking with Isotonic Riboflavin Solution without Dextran | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- Dekstransız izotonik riboflavin solüsyonu ile yapılan kornea kollajen çapraz bağlama uygulaması sırasında kornea kalınlığı.pdf
- Boyut:
- 66.71 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin (Full Text)