Ön Kamara Bulanıklığının Gün İçi Değişimi

dc.authoridMehmet Adam: 0000-0003-0552-5212
dc.authoridMehmet Okka: 0000-0002-3908-1042
dc.authoridHürkan Kerimoğlu: 0000-0002-5601-2049
dc.authoridHamiyet Pekel: 0000-0002-3697-3379
dc.authoridBanu Turgut Öztürk: 0000-0003-0702-6951
dc.authoridBanu Bozkurt: 0000-0002-9847-3521
dc.authoridSüleyman Okudan: 0000-0002-9491-1459
dc.contributor.authorAdam, Mehmet
dc.contributor.authorOkka, Mehmet
dc.contributor.authorKerimoğlu, Hürkan
dc.contributor.authorPekel, Hamiyet
dc.contributor.authorTurgut Öztürk, Banu
dc.contributor.authorBozkurt, Banu
dc.contributor.authorOkudan, Süleyman
dc.date.accessioned2020-01-18T21:04:00Z
dc.date.available2020-01-18T21:04:00Z
dc.date.issued2015
dc.departmentNEÜ, Meram Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Göz Hastalıkları Anabilim Dalıen_US
dc.description.abstractAmaç: Laser flaremetre cihazı ile yapılan ön kamara bulanıklık ölçümlerin ideal zamanı ve tekrarlanabilirliğinin araştırılması. Gereç ve Yöntem: Kırk beş gönüllünün sabah saat 8.00da laser flaremetre cihazı ile ön kamara bulanıklık ölçümleri yapılmış ve bu ölçümler aynı gün saat 12.00 ve saat 16.00da tekrarlanmıştır. Bulgular: Gönüllülerin 25i (55,5) kadın ve 20si (44,5) erkekti ve ortalama yaşları 28,677,40 yıldı. Olguların oftalmolojik muayenelerini takiben alınan ortalama ön kamara bulanıklık ölçümleri sabah saat 8:00da 5,941,41 foton msn, saat 12de 5,651,45 foton/msn, saat 16.00da 5,791,20 foton/msn idi. Ölçümler arasında anlamlı bir farklılık saptanmadı (p0,08). Katılımcıların göz rengine göre yapılan alt grup analizinde de kahverengi, ela ve yeşil göz renkler arasında anlamlı bir farklılık bulunmamıştır. Korelasyon analizinde gün içinde alınan üç ölçümün de yaşla korele olduğu görülmüştür. Sonuç: Ön kamara bulanıklık ölçümlerinde sağlıklı bireylerde gün içerisinde anlamlı bir değişiklik saptanmamıştır ancak yaşla pozitif korelasyon göstermektedir. Bu nedenle gün içindeki tüm ölçümler güvenilirdir ve tekrarlanabilirliği yüksektir.en_US
dc.description.abstractObjectives: To investigate the ideal time and reproducibility of anterior chamber flare measurements. Materials and Methods: Anterior chamber flare measurements were performed with laser flaremetre device at 8 am to 45 volunteers and these measurements were repeated on the same day at 12 pm and 4 pm. Results: Twenty-five of the volunteers were women and 20 were men; mean age was 28.67 7.40 (18-49) years. The mean anterior chamber flare measurements taken following the ophthalmologic examination were 5.94 1.41 foton msn at 8 am, 5.65 1.45 foton/msn at 12 pm, and 5.79 1.20 foton/msn at 4 pm. No statistical difference was found between the measurements. Subgroup analysis according to eye color, revealed no significant difference between flare measurements in brown, hazel, and green eyes. Correlation analysis demonstrated association between age and all flare measurements within the day. Conclusion: No significant diurnal change was detected in the flare measurements of our study subjects but positive correlation with age was observed. Hence, all flare measurements within a day are reliable and have high repeatability in healthy subjects.en_US
dc.identifier.citationOkka, M., Pekel, H., Adam, M., Kerimoğlu, H, Turgut Öztürk, B., Bozkurt, B., Okudan, S. (2015). Ön kamara bulanıklığının gün içi değişimi. Türk Oftalmoloji Dergisi, 45, 2, 52-55.en_US
dc.identifier.endpage55en_US
dc.identifier.issn1300-0659en_US
dc.identifier.issn2147-2661en_US
dc.identifier.issue2en_US
dc.identifier.startpage52en_US
dc.identifier.urihttps://app.trdizin.gov.tr/makale/TVRjd056YzJOZz09/on-kamara-bulanikliginin-gun-ici-degisimi
dc.identifier.urihttps://hdl.handle.net/20.500.12452/1736
dc.identifier.volume45en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.language.isotren_US
dc.relation.ispartofTürk Oftalmoloji Dergisien_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US]
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectÖn kamara bulanıklığı
dc.subjectGün içi değişim
dc.subjectLaser flaremetre
dc.subjectAnterior chamber flare
dc.subjectDiurnal variation
dc.subjectLaser flaremetre
dc.titleÖn Kamara Bulanıklığının Gün İçi Değişimien_US
dc.title.alternativeDiurnal Variation of Anterior Chamber Flareen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Ön kamara bulanıklığının gün içi değişimi.pdf
Boyut:
133.94 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin (Full Text)