Ön Kamara Bulanıklığının Gün İçi Değişimi
dc.authorid | Mehmet Adam: 0000-0003-0552-5212 | |
dc.authorid | Mehmet Okka: 0000-0002-3908-1042 | |
dc.authorid | Hürkan Kerimoğlu: 0000-0002-5601-2049 | |
dc.authorid | Hamiyet Pekel: 0000-0002-3697-3379 | |
dc.authorid | Banu Turgut Öztürk: 0000-0003-0702-6951 | |
dc.authorid | Banu Bozkurt: 0000-0002-9847-3521 | |
dc.authorid | Süleyman Okudan: 0000-0002-9491-1459 | |
dc.contributor.author | Adam, Mehmet | |
dc.contributor.author | Okka, Mehmet | |
dc.contributor.author | Kerimoğlu, Hürkan | |
dc.contributor.author | Pekel, Hamiyet | |
dc.contributor.author | Turgut Öztürk, Banu | |
dc.contributor.author | Bozkurt, Banu | |
dc.contributor.author | Okudan, Süleyman | |
dc.date.accessioned | 2020-01-18T21:04:00Z | |
dc.date.available | 2020-01-18T21:04:00Z | |
dc.date.issued | 2015 | |
dc.department | NEÜ, Meram Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Göz Hastalıkları Anabilim Dalı | en_US |
dc.description.abstract | Amaç: Laser flaremetre cihazı ile yapılan ön kamara bulanıklık ölçümlerin ideal zamanı ve tekrarlanabilirliğinin araştırılması. Gereç ve Yöntem: Kırk beş gönüllünün sabah saat 8.00da laser flaremetre cihazı ile ön kamara bulanıklık ölçümleri yapılmış ve bu ölçümler aynı gün saat 12.00 ve saat 16.00da tekrarlanmıştır. Bulgular: Gönüllülerin 25i (55,5) kadın ve 20si (44,5) erkekti ve ortalama yaşları 28,677,40 yıldı. Olguların oftalmolojik muayenelerini takiben alınan ortalama ön kamara bulanıklık ölçümleri sabah saat 8:00da 5,941,41 foton msn, saat 12de 5,651,45 foton/msn, saat 16.00da 5,791,20 foton/msn idi. Ölçümler arasında anlamlı bir farklılık saptanmadı (p0,08). Katılımcıların göz rengine göre yapılan alt grup analizinde de kahverengi, ela ve yeşil göz renkler arasında anlamlı bir farklılık bulunmamıştır. Korelasyon analizinde gün içinde alınan üç ölçümün de yaşla korele olduğu görülmüştür. Sonuç: Ön kamara bulanıklık ölçümlerinde sağlıklı bireylerde gün içerisinde anlamlı bir değişiklik saptanmamıştır ancak yaşla pozitif korelasyon göstermektedir. Bu nedenle gün içindeki tüm ölçümler güvenilirdir ve tekrarlanabilirliği yüksektir. | en_US |
dc.description.abstract | Objectives: To investigate the ideal time and reproducibility of anterior chamber flare measurements. Materials and Methods: Anterior chamber flare measurements were performed with laser flaremetre device at 8 am to 45 volunteers and these measurements were repeated on the same day at 12 pm and 4 pm. Results: Twenty-five of the volunteers were women and 20 were men; mean age was 28.67 7.40 (18-49) years. The mean anterior chamber flare measurements taken following the ophthalmologic examination were 5.94 1.41 foton msn at 8 am, 5.65 1.45 foton/msn at 12 pm, and 5.79 1.20 foton/msn at 4 pm. No statistical difference was found between the measurements. Subgroup analysis according to eye color, revealed no significant difference between flare measurements in brown, hazel, and green eyes. Correlation analysis demonstrated association between age and all flare measurements within the day. Conclusion: No significant diurnal change was detected in the flare measurements of our study subjects but positive correlation with age was observed. Hence, all flare measurements within a day are reliable and have high repeatability in healthy subjects. | en_US |
dc.identifier.citation | Okka, M., Pekel, H., Adam, M., Kerimoğlu, H, Turgut Öztürk, B., Bozkurt, B., Okudan, S. (2015). Ön kamara bulanıklığının gün içi değişimi. Türk Oftalmoloji Dergisi, 45, 2, 52-55. | en_US |
dc.identifier.endpage | 55 | en_US |
dc.identifier.issn | 1300-0659 | en_US |
dc.identifier.issn | 2147-2661 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.startpage | 52 | en_US |
dc.identifier.uri | https://app.trdizin.gov.tr/makale/TVRjd056YzJOZz09/on-kamara-bulanikliginin-gun-ici-degisimi | |
dc.identifier.uri | https://hdl.handle.net/20.500.12452/1736 | |
dc.identifier.volume | 45 | en_US |
dc.indekslendigikaynak | TR-Dizin | en_US |
dc.language.iso | tr | en_US |
dc.relation.ispartof | Türk Oftalmoloji Dergisi | en_US |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı | en_US] |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Ön kamara bulanıklığı | |
dc.subject | Gün içi değişim | |
dc.subject | Laser flaremetre | |
dc.subject | Anterior chamber flare | |
dc.subject | Diurnal variation | |
dc.subject | Laser flaremetre | |
dc.title | Ön Kamara Bulanıklığının Gün İçi Değişimi | en_US |
dc.title.alternative | Diurnal Variation of Anterior Chamber Flare | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- Ön kamara bulanıklığının gün içi değişimi.pdf
- Boyut:
- 133.94 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin (Full Text)