Konik Işınlı Bilgisayarlı Tomografi Kullanılarak Elde Edilen İki Ve Üç Boyutlu Lateral Sefalometrik Analizlerin Karşılaştırılması

dc.contributor.authorBüyük, Süleyman Kutalmış
dc.contributor.authorHalıcıoğlu, Koray
dc.contributor.authorÇelikoğlu, Mevlüt
dc.contributor.authorŞekerci, Ahmet Ercan
dc.contributor.authorÜnal, Tuba
dc.contributor.authorKılkış, Doğan
dc.date.accessioned2020-01-18T21:03:41Z
dc.date.available2020-01-18T21:03:41Z
dc.date.issued2014
dc.departmentNEÜ, Diş Hekimliği Fakültesi, Ortodonti Anabilim Dalıen_US
dc.description.abstractAmaç: Bu çalışmanın amacı, konik ışınlı bilgisayarlı tomografi (KIBT) kullanılarak elde edilen iki (2D) ve üç boyutlu karşılaştırılmasıdır. Gereç ve yöntem: 25 hastanın (12 erkek ve 13 bayan; ortalama yaş: 25,22 4,92 yıl; yaş dağılımı: 18-35 yıl) 2D ve 3D olarak çizilen lateral sefalometrik görüntüleri bu çalışmanın materyalini oluşturmaktadır. Tüm KIBT görüntüleri KIBT (NewTom 5G, QR Verona, Italy) kullanılarak supin pozisyonunda alınmıştır. DICOM dosyaları SimPlant yazılımı (SimPlant Pro 2011, Materialise, Leuven, Belgium) kullanılarak elde edildi ve tüm ölçümler bu program kullanılarak yapılmıştır. Sefalometrik analizlerin karşılaştırılabilmesi için 8 iskeletsel, 8 dişsel ve 3 yumuşak dokuyu içeren toplam 19 parametre (14 açısal ve 5 boyutsal) ölçülmüştür. Her iki yöntemle belirlenen ölçümler eşleştirilmiş t-testi kullanılarak karşılaştırılmıştır. Ayrıca, Pearson korelasyon katsayıları hesaplanmıştır. Bulgular: 2D ve 3D olarak çizilen lateral sefalometrik filmlerin tekrarlanabilirliği kabul edilebilir sınırlar içinde bulunmuştur. Eşleştirilmiş t testi sonucunda; SN-GoGn () (p 0,011), MP-PP () (p 0,006), Y () (p 0,009) ve IMPA () (p 0,002) açılarında, N-Me (mm) (p 0,043) ve U1-NA (mm) (p 0,000) ölçümleri arasında istatistiksel olarak anlamlı farklılık olduğu görülmüştür. Pearson korelasyon katsayısı U1-NA () (r 0,575) ve nasolabial açı () (r 0,641) ve L1-APog (mm) (r 0,658) mesafesi hariç tüm ölçümlerde yüksek olarak tespit edilmiştir. Sonuç: KIBT görüntüleri kullanılarak elde edilen 2D ve 3D lateral sefalometrik analizler karşılaştırıldığında, Pearson korelasyon hemen hemen tüm ölçümlerde yüksek olmasına rağmen, SN-GoGn (), MP-PP (), Y açısı () ve N-Me (mm) gibi dik yön ile ilgili değerlerde istatistiksel olarak anlamlı farklılık gözlenmiştir.en_US
dc.description.abstractAim: The aim of the present study was to compare lateral cephalometric analyses made three dimensionally (3D) and two dimensionally (2D) obtained from Cone Beam Computed Tomography (CBCT). Material and method: The material of this study included that lateral cephalometric images of 25 patients (12 males and 13 females; mean age: 25.22±4.92 years; age range: 18-35 years) were traced by 3D and 2D methods. All CBCT images were obtained in supine position by using CBCT (NewTom 5G, QR Verona, Italy). DICOM files obtained from the CBCT scans were reconstructed by SimPlant (SimPlant Pro 2011, Materialise, Leuven, Belgium) software. All measurements were made using this software. A total of 19 parameters including 8 skeletal, 8 dental, and 3 soft tissue variables (14 angular and 5 linear) were measured to comparison of cephalometric analyses. The measurements determined by each method were compared with a paired t-test. In addition, Pearson correlation coefficients were calculated. Results: Intra-observer reliability for both 2D and 3D methods was acceptable. The results of paired t-test showed that significant differences were observed for SNGoGn (°) (P 0.011), MP-PP (°) (P 0.006), Y angle (°) (P 0.009), IMPA (°) (P 0.002), N-Me (mm) (P 0.043), and U1-NA (mm) (P 0.000). Pearson correlation coefficients were high for all measurements except U1-NA (°) (r 0.575), nasolabial angle (°) (r 0.641), and L1- APog (mm) (r 0.658). Conclusion: When lateral cephalometric analyses made by 3D and 2D obtained from CBCT were compared, statistically significant differences were observed in parameters about vertical dimension as SN-GoGn (°), MPPP (°), Y angle (°), and N-Me (mm) despite Pearson correlation coefficients were high for almost all measurements.en_US
dc.identifier.citationBüyük, S. K., Halıcıoğlu, K., Çelikoğlu, M., Şekerci, A. E., Ünal, T., Kılkış, D. (2014). Konik Işınlı Bilgisayarlı Tomografi Kullanılarak Elde Edilen İki Ve Üç Boyutlu Lateral Sefalometrik Analizlerin Karşılaştırılması. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi, 24, 2, 213-218.en_US
dc.identifier.endpage218en_US
dc.identifier.issn1300-9044en_US
dc.identifier.issn1300-9044en_US
dc.identifier.issue2en_US
dc.identifier.startpage213en_US
dc.identifier.urihttp://app.trdizin.gov.tr/publication/paper/detail/TWpNMU5EYzBOQT09
dc.identifier.urihttps://hdl.handle.net/20.500.12452/1649
dc.identifier.volume24en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.language.isotren_US
dc.relation.ispartofAtatürk Üniversitesi Diş Hekimliği Fakültesi Dergisien_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US]
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDiş Hekimliğien_US
dc.subjectKonik Işınlı Bilgisayarlı Tomografien_US
dc.subjectSefalometrien_US
dc.subjectLateral Sefalometrik Analizen_US
dc.subjectCone Beam Computed Tomographyen_US
dc.subjectCephalometryen_US
dc.subjectLateral Cephalometric Analysesen_US
dc.titleKonik Işınlı Bilgisayarlı Tomografi Kullanılarak Elde Edilen İki Ve Üç Boyutlu Lateral Sefalometrik Analizlerin Karşılaştırılmasıen_US
dc.title.alternativeComparison Of Lateral Cephalometric Analyses Made Three Dimensionally And Two Dimensionally Obtained From Cone Beam Computed Tomographyen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Büyük, Süleyman Kutalmış.pdf
Boyut:
296.54 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin/ Full Text